GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

No Hot Water At All?

Hi, I am having problems with my hot water - both central heating and hot water from the taps. The water from the hot water taps and the central heating is cold, it will not heat up at all despite the gas boiler working. I have replaced the 3-way Honeywell mid-position valve (head and wet end). I have also checked the Grudfos recirc pump, which is working fine.

If I leave the heating system off for 4 or 5 hours and then switch on again, the boiler fires up but switches off after about 5-minutes. It is like the gas boiler is sensing the temperature is too high, then shutting down the boiler. Although the recirc pump and mid position valve are working fine, it seems like the water is just not circulating from the gas boiler down stairs, through the recirc pump and mid position valve up stairs, to the boiler water storage tank etc. I don't know if the system is air locked, but I cannot get hot water from the gas boiler to the mid position valve area. I have tried everything - no joy.
Sean Gallagher, September 2009
I agree with gas man, check there is water in the header tank, lossen a nut on the 3 way valve, take care see if you get air or water, if water, I would be double checking pump I have had them be for where they are running but the shaft had brocken so the impeller was not turning.

erj, September 2009
Sounds like u got no circulation. Check 1 for air locks 2 that the pump impellor is actually turning 3 there is water in system

Gasman, September 2009
link Click here to see other fixes for Honeywell.