andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Click here to ask your question

heating probs?

I have a Chafetaux Britony combi boiler that works fine when you need hot water. The problem sarts when you switch the heating on. It fires up no problem then after about 45 seconds the flame goes out the pump runs on for about three minutes and it seems as though the heat generated is being pushed up the hot water pipe rather than the heating.
Do I need a new three way valve or do I need a new flow switch
Rod Thurland, September 2009
its a Chafetaux boiler chuck it in the bin !!!!

joseph, September 2009
probably faulty 3 way valve, if flow switch was faulty it wouldn't fire.

Ian, September 2009
Thermostatic rad valves are all open

rod, September 2009
Are thermostatic rad valves fitted ? check they are not jammed closed

a, September 2009