Andy asked ... How can I mend my MacAlistair 450w hedge trimmer?    |    Felix asked ... Hitachi vt-m70em?    |    Katie Bond asked ... Fixing auto threader on Baby Lock Enlighten Overlocker?    |    Chris. asked ... Miele W800 novotronic washing machine?    |    Larry asked ... How to stop my steam iron from leaking. Model dw2463 Rowenta?    |    Click here to ask your question

worcester 28i junior rsf?

i have no heating or hot water , the fan doesnt seem to kick in and im after advice how i can check if its pcb fault , i am gsr but i install dont really touch faults . thank you
matt2411, September 2009
Funnily enough I have just looked at a boiler that is doing just that, fan spins for a second then light starts flashing. Is that def a PCB fault?

Rob, October 2009
Get a Gas Safe Registered Engineer to look at it. You should not even take a screw driver to it if you have to ask that question.

Gareth, October 2009
easiest way to identify the most common fault i've come across on these boilers is; to take off the combustion chamber cover then try to fire the boiler up, if the fan runs for about 2 seconds then stops and the fault light flashes then it'll be the pcb thats at fault. there are 2 pcb's for this boiler so give worcester a call to make sure you get the right one, it depends which gas valve it has fitted which determines the pcb. also, make sure you re-fit the code plug to the new board.

Ian, October 2009
link Click here to see other fixes for Worcester.