hi mate i have a 28i and have been experiencing same locking out, i have had the pcb out and no signs of any dry joints, the fan is working fine i checked this by disconnecting power to the boiler and then setting CH to constant when you turn power back on the boiler fires up but no spark then fault light starts again. when i try again i noticed there was a noise missing as the boiler tryd firing ,a clink sound. found this to be pressure switch. on the top of boiler should be red valve cap,not the one on the expansion vessel the one on front left, i turned off gas supply and put a pipe on to it and created a vacum (sucked it was desperate at this point ) and the clink noise was back, still with gas off i powered the boiler and sucked pipe and it sparked. looking at pressure switch it appeared fine when i removed it, it had loose bits inside. i reassembled the switch but left disconnected the white pipe to the valve but left it connected at fan and top of boiler powered it again and it fired perfectly. briefly knowing fan and flue were working fine and re assembled boiler turned gas back on and worked fine. i have ordered a new switch by internet and am convinced this is at fault. if this fails i going to call out worcester as i believe they have diagnostic tool. hope this can help
chris, October 2009