GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

How can I fix my heating system?

I have just fitted a new radiator onto an existing open vented system running from a Glow-worm 30HXI boiler. The problem I have is that the flow pipe to the rad is getting warm but the return pipe isn't! What can I try to rectify this ?
Huw, October 2009
Its airlocked....try bleeding the radiator again - it could help if you turned some of the other rads off to increase the pressure. Failing that, turn off the rad valves, disconnect from rad - which will drain down- and open them again, one at a time, into a shallow tray. Reconnect them, open both slowly at the same time, rad bleed valve open.

John, October 2009