Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

Baxi bermuda boiler - insufficient pilot light?

Baxi bermuda GF Super boiler - unsuccessfully trying to re-light the pilot light as per instructions . Iget a weak flame but it is insufficeint to fire the boiler. No particular draughts. Falme will remain but when grey push button is released , the flame will extinguish
Nigel S, October 2009
can i light the baxi bermuda gf and lfe3 by fire or matches

tom, December 2011
you need a gas safe eng to look at it, could be blocked poilet, t/coupling or gas valve.
Should not be to expansive

erj, October 2009
I had continuing problems with a weak pilot flame on a completely different boiler - the weak flame was not providing enough heat to properly convince the control board that the pilot flame was alight. The thermocouple signal to the control was too small because of the weak flame. Because the system was unable to "see" the pilot flame it shut off the gas as a safety measure....

The cause was dirt blocking the hole in the pilot flame injector. After cleaning it the flame was twice the size and everything worked a treat. Private persons are not supposed to interrupt the "gas-way" - a certificated engineer should make safety checks after this kind of work.

Peccavi, October 2009
thermocouple , worst case gas valve

tim, October 2009