Morne asked ... My defy dtl 125 toploader?    |    Ernie asked ... How to fix gearchange ldv maxus van 2006?    |    Cuckoo asked ... Changing batteries on a fixed bt corded phone?    |    Marc Nollid asked ... Nissan Micra mk 5 2018 rear seat mecanism?    |    Maggie asked ... New Home 535?    |    Click here to ask your question

central heating guage on the boiler rises to 2.8bars when heating is on?

What is causing the guage on the combo boiler (Worcester) to rise to nearly 3 bars after a few minutes when I put the central heating on?
Ronald Ellams, October 2009
Probably the expansion vessel has little or no air in it....if you can drop the boiler pressure to zero and then put a car tyre pressure gauge onto the expansion vessel valve, you need 10 psi in there.... so out with the foot pump!

John, October 2009