3 hours ago T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Mike asked ... Bosch WTA74200GB Vented Dryer?    |    Click here to ask your question

Potterton 80 not firing up. no 230v coming from the terminal T7 and T8?

Hi,

I have a potterton 80, and there is no voltage coming out of the Terminal 7 and 8 to drive the fan, what could be the problem?
Ravi, November 2009
I am all out of suggestions - if the fuse is good and there's a call for heat and the boiler is on (has power) and the overtemp has not tripped and the boiler stat is not on zero and you still have no 230V between 7 & 8 then the only thing I can think of is a wiring fault - when you changed the control board you may have failed to connect something correctly - it does happen.

Perhaps it's time for an expert - not a well intentioned amateur like me...

Continuing good luck...

P, November 2009
hi Peccavi,

I have checked that. I have taken the fan connector off, and checked for 230v at the t7 and 8, but im still not getting any voltage. i have changed the control board now, and im still getting no voltage or spark at the boiler.

please advise.

thanks in advance

rav, November 2009
There should be 230V Between T7 & T8 for the fan to run...

There may be:
No call for heat
Boiler turned off
Fuse on PCB blown
Bad connection

The fan may be short circuit - remove the fan connections - replace the fuse if blown - make the call for heat and measure voltage between 7 & 8 - if you now have 230V then the fan may be blowing the fuse...

Good luck...

Peccavi, November 2009