Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Jerry asked ... Alpine 7287?    |    Guy asked ... Gaggenau fridge alarm problem?    |    Click here to ask your question

Is there any alternative to an oil lifter on Danesmoor 15/19?

The engineer has tried everything but not sure of the details, after the boiler went into lockout. Months after we still have had no success, the oil is getting to the tiger loop but cutting out after about a minute... hence having the oil lifter fitted on the outside wall which is too unsightly. Is there anything else that can be done? getting desperate now as it has been months being worked on. By the way the pump is a Danfloss.
June, November 2009
A Tigerloop should be able to pull up oil to 3.5Mtrs, so unless your boiler is in an upstairs room an oil lifter should not be needed, I am concerned that an Oil lifter has been fitted externally as these are Electrically operated and generally are not weather proof???

Sounds to me like you may have had air leaking into the suction pipe to your Tiggerloop, or there is a problem with the oil burner such as oil pumnp of solenoid coil etc etc

www.elanar.co.uk, November 2009