Bob asked ... Charger fault?    |    Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    Click here to ask your question

what is fault F75 on vaillant ecotec 360?

boiler does not come on so no hot water or heating.
Elaine, November 2009
did you press your reset button

jacqui, December 2010
how can i mend code f75?

shirlee-lee jenkins, October 2010
In the manual it says no pressure rise was detected on turning on the pump - water pressure sensor and or pump defective, air in heating system, quick bleeder defective, too little water in appliance, check adjustable by-pass, connect external expension vessel to return.
Ensure you have at least 1 bar pressure in system via guage or button, if not add some water via the linked water tap and pipe. Also bleed your radiators to ensure no air in system.

hope helps

helpful, January 2010
hi done one today, fault f75, renewed pressure switch and pump, all working fine now.

ng plumbing and heating, November 2009
has the pressure dropped on the gauge on the front of the boiler

b, November 2009