narnia asked ... Matsui ct-111ss?    |    Jason asked ... How to fix handset problems ( intercom ) and access control?    |    andy asked ... Samsung VP-D60 camcorder?    |    Shopper asked ... Poor Renault Radio Reception?    |    reg bardle asked ... Lg 7kg dd?    |    Click here to ask your question

ideal classic ff260 fan on top partial seized?

The boiler will not fire up until i flick this fan as hard as i can
Can I replace this fan if so where do I get one.
It appears to be just held on by three grip washers
Tim P, January 2010
Make sure the two spade connectors on fan are pushed in !

fitz, September 2010
Hi, I have just had the same thing happen. It is likely to be one of the bearings has packed up. It's not as easy to get the fan off as you think. You need to undo the two bars up the front with the twin nuts on top. Then there a small bolt just behind the fan to take off. Then remove the top assembly front just above the cast iron part and lift it clear. You should then be able to dismantle the motor and get to the bearings. I flicked mine a few times and got it going for a few more days, but it eventually packed up tonight 8th Feb. So, in my case I need a new fan - does anyone know where I can get one cheaply and easily ?

many thanks

Pablo

pablo, February 2010
hi

pablo, February 2010
there is more to it than that
its best to get an engineer to do it

b, January 2010