Andy asked ... How can I mend my MacAlistair 450w hedge trimmer?    |    Felix asked ... Hitachi vt-m70em?    |    Katie Bond asked ... Fixing auto threader on Baby Lock Enlighten Overlocker?    |    Chris. asked ... Miele W800 novotronic washing machine?    |    Larry asked ... How to stop my steam iron from leaking. Model dw2463 Rowenta?    |    Click here to ask your question

How To Replace Pressure Relief Valve on Combi Boiler?

Dear Site,

We have a Baxi Combi 105e, which appears to have a weak PRV, in so much that it is losing pressure from 1.5bar to>0.5 bar over the period of a day. When filling the loop, it is impossible to refil past 2bar, as water passes out from the overfil pipe outside, via the pressure relief valve. Assuming the PRV is faulty, how is the PRV replaced -is it necessary to fully drain the system first? Many thanks in advance. Rob.
Rob, January 2010
you can turn of the flow and return pipes on the boiler, the two on the out side edges of the boiler under neath, turn the rad cap on te PRV till the water stops running then you can take the valve out, some unscrew some are held in with a grum screw. Once you have fitted the new one ceck the persurin te red expansion vessel on the back ou the boiler wit a tyr gage should be about 1.5 bar if not refill with a bike pump. turn on te valves and refil as normal

erj, January 2010