GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

How can i fix my Dimplex storage heater?

Hi all,

I have a Dimplex storage in my leaving room, which stopped working. The manual part is, but it doesn’t store any heat at night. I do not have the reference or any booklet to go with it.
I think it stopped working because clothes were put on to dry (oopsss)

When I checked the fuse box in the hall way, no red light was on during the night. I have been told, it should (not sure if this is correct or not)
I've read the forum for solutions, and found few about the reset trips.

I took down the front and top part of the heater yesterday.
I found the little "circular" white trip. However, I couldn’t take out the metal cover where the "input and output" sockets are. The screws seem damaged, or I’m simply not strong enough :)
I tried to push down the trip, without success and it actually felled off (I kept it). I put everything back up (without the trip) and turned on the storage socket on.
During the night, the red light was on at the fuse box. However the heater was completely cold this morning, and the red light stayed on, even after 8am, when I actually switch off the heater storage socket.

Did I do a bit mistake by completely taking out the white trip?

Any suggestions so my heater starts storing heat at night again?

Many thanks
Anne
Anne, February 2010
Contact www.tilmar.co.uk for storage heater repair, replace and removal services.

Martin, August 2010
do you have two switches next to the heater if so one will be the convector and the other the night storage check the fuse on the night side in the switch on the wall if ok then turn off both power supplys and at the board then take of front cover off and on the tap were the components are is thermostate and heat control and some models have resets if reset does not work the its either thermostate which starts at the top with a thin wire going down the back of the heater with a small metal bar under the heater test these out and test the elements out to see if ok most comon fault is themostat and reset cost for both parts from dimplex about £70 but if unsure please contact an electrian for guidence

gordon, May 2010
link Click here to see other fixes for Dimplex.