Alan asked ... Problem with JCB 3CX transmission?    |    Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Click here to ask your question

potterton flamingo 50 won't ignite - water pressure?

I believe the water pressure switch may need re setting .
how do I do it? ( lost the manual)
There is / was a pilot light and the thermostat sends a signal to ignite main flame but nothing happens,
I've recently bled a lot of air from the CH system
Alan, May 2006
Hi, If you can get to your water tanks, [there should be two] one is larger than the other,look in the small one it should be the expansion for the boiler,the ball valve may be stuck up and the tank empty,If so push ball valve down so water enters stay with it to make sure it shuts of, bleed the rads making sure that there is water in the expansion at all times,if this is the case the boiler should relight,If this is the case it would be wise to replace the ball valve some time soon.

jayc, May 2007