Toddy asked ... Pdw5048tms saw?    |    Karen asked ... Royal 480nt cash register?    |    andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    Click here to ask your question

Vokera boiler pressure loss problem?

I have a vokera linea boiler and over the last couple of weeks it has been losing pressure day by day.Nothing drastic but i am having to top up pressure every 4-5 days.Boiler was serviced at end of Dec and was given clear bill of health.We have recently had an electric shower fitted but didnt think this would affect it ? can you help or do i need a plumber ?
thanks
Gary Macindoe, March 2010
Check the external wall where the boiler is fitted. There will be a 15mm copper pipe (Blow Off). If you can, try and feel if this is dry. Pressure can be lost this way. If it is dripping it will either be an expansion vessel/hose to vessel problem (Turn heating on and see if pressure increases sharply) or a faulty Pressure relief valve

Paul, March 2010
link Click here to see other fixes for Vokera Linea.