GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

My Heatline viso 24 will not heat the DHW to a decent temp?

Could anyone tell me why the DHW on my boiler is not hot enough. The temp is set to max and the burners are lit and there are no fault lights on.
Simon Sheffield, March 2010
I have the same problem though in my case the red LED on the front panel is flashing. I need to replace the DHW sensor, when this sensor fails the boiler will carry on supplying hot water but restricts it to 64degs cent. only. It does this by using the flow sensor and CH sensor to regulate the temp. at the taps

charlyfarly, May 2010