andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Click here to ask your question

My Heatline viso 24 will not heat the DHW to a decent temp?

Could anyone tell me why the DHW on my boiler is not hot enough. The temp is set to max and the burners are lit and there are no fault lights on.
Simon Sheffield, March 2010
I have the same problem though in my case the red LED on the front panel is flashing. I need to replace the DHW sensor, when this sensor fails the boiler will carry on supplying hot water but restricts it to 64degs cent. only. It does this by using the flow sensor and CH sensor to regulate the temp. at the taps

charlyfarly, May 2010