GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

Britony Combi SE 70 80 Error + Low Pressure?

Hi all,

My boiler is showing the "No Flame Detected" error but in addition the CH pressure gauge shows that the pressure is only about .75.
I have tried adjusting the valves on the filling loop but it doesn't seem to make any difference. I am assuming that the filling loop is the silver pipe under the boiler...?
Anyone have any ideas?
I may be being a bit of an idiot and not using the valves properly on the loop, I suppose...
Thanks a lot.
Mat, March 2010
britony se 80. pressure should be 1.5bar.the loop is under the boiler joining the incoming feed to the central heating these are the 2 last pipes on the right.open valve on this pipe until 1.5 shows.if you have lost pressure you may have a leak.no flame detection means the ionization electrode has not detected a flame.maybe electrode has failed (£40) or pcb has failed (£130+). leak needs sorting to see if 70 80 fault goes.when power is isolated elecrode contacts can be cleaned and pcb checked out.

xs11, March 2010
link Click here to see other fixes for Britony Combi SE.