Suzanne asked ... Washing programme stops after 3 minutes?    |    Rif asked ... Kenwood Dishwasher KID60S20 leaking from front?    |    Fraser asked ... Spares for power craft ppcs 38cc?    |    FB asked ... Toyota Yaris Speed Camera Warning Beep?    |    Ela asked ... Worcester 30 Cadillac combi boiler won’t fire up and the EA?    |    Click here to ask your question

potterton profile 60e?

fan kicks in and then cuts out without ignition taking place then repeats again and again without success any ideas
mick, April 2010
check the pressure switch, remember the process
1. ready to go
2 board tells fan to run
3. prove fan running (PRESSURE SWITCH)
4 once fan proved ignition process can start
5 pilot ignition
6 prove flame
7, main burner on

HEATWISE, April 2010