Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    tom schwartz asked ... Bosch maxx 6?    |    Noman asked ... Reverse light switch?    |    Suzie asked ... Stuck Feed dog?    |    Click here to ask your question

Mira Essentials Shower (9.5KW) electrical failure?

Wonder if anyone can help? I have an Essentials shower, only a couple of years old. Switched it on from the switch outside the bathroom but the shower wouldn't work. The orange indicator light doesn't come on. I've checked the electrical connections from the fuze to the switch and the connections in the shower itself....Both appear fine. Using a volt meter confirmed there was 'juice' getting to the unit.

Any suggestions would be greatly appreciated.
Charley, May 2010
Sorry for the delay...been working Nightshift. On the basis of your answer I had another ferret around. Transpired th problem was with the DP Switch ( The contacts had melted through but it wasn't apparent!) Simply changed the DP switch and voile...Shower now works!! Many many thanks again for your time. You have saved me a small fortune. Much appreciated.

Kind regards

Charley

Charley, May 2010
do live to neutral see if you get 230v
you may have a neutral fault.

hi-spec plumbing & heating (essex), May 2010
Thanks for the quick reply.....Live to Earth (Green)
Hope this helps.

Charley, May 2010
how did you check for power at shower ?
live to earth or live to neutral ?

hi-spec plumbing & heating (essex), May 2010