andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Click here to ask your question

fan running no ignition?

I have a baxi solo which a friend has asked me to take a look at i am boilers registed but mainly work on cookers the fault is the fan runs but there is no ignition.
steven davis, June 2010
Check air pressure switch and that the tubes from it havent become twisted, located at top of boiler. poss ventury block or air pressure switch has gone. Does the pilot light on control light up?? if so poss blocked pilot injector

Baxi man, June 2010
I am not qualified or experienced - so don't expect wisdom.

Ignition is conditional on the fan running - a pressure switch senses the correct pressures in the enclosure and signals the control electronics accordingly.

Good luck...

Peccavi, June 2010
check the ventury on the fan is clean and the air pressure switch after that could be the PCB

erj, June 2010
link Click here to see other fixes for Baxi Solo.