mike asked ... Fisher & Paykel 913t dishwasher?    |    Emma asked ... Foot pedal smoking?    |    Morne asked ... My defy dtl 125 toploader?    |    Ernie asked ... How to fix gearchange ldv maxus van 2006?    |    Cuckoo asked ... Changing batteries on a fixed bt corded phone?    |    Click here to ask your question

Potterton Netaheat Electronic 6-10 Won't Ignite?

Hi all,

I have a Potterton Netaheat Electronic 6-10 boiler that is on the blink. Usually when it starts up I hear the fan start running for a couple of seconds, there is a click, then another click and the boiler lights. For some reason now the boiler ignites fine the first time however after a couple of minutes it cuts off. When it then starts again it won't ignite any more. I hear the fan start however there are no clicks and the fan switches off again. The boiler then continues this cycle of the fan starting, running for a couple of seconds and the stopping.

The irritating thing about this problem is that it is intermittant. One evening it will work fine, and the next it won't. I have had a guy out to look at it twice now (on the second occasion he serviced it) however on both occasions the boiler was working fine so he couldn't find a problem with it.

Any ideas?

Regards,

Rob

PS - I know that this boiler is getting on a bit, however I am due to move house in two weeks time so don't really want to have to replace it now.
Rob, June 2010
The usual problem is a blockage in the pipe going to the Air Pressure Valve .(This switches a microswitch ON (using a vacuum) providing the fan is running OK


It goes via a restrictor in the plastic tubing and the quickest cure is to pull one end off and suck/blow the pipe a few times (hearing the micro switch click ON/OFF)

Obviously observe ALL SAFETY PROCEDURES !

Electric off etc before working on it

Joe, July 2010