Karen asked ... Royal 480nt cash register?    |    andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    Click here to ask your question

Ariston Mircrogenus HE 32 MFFI - Hot water not getting up to temp?

Hi Guys,
I have a HE32 MFFI Boiler,
recently the Hot water has not been getting up to temperature. it runs hot and cold intermittently,
even with the water set at max .. Any ideas ?

Ariston have quoted £220 to come out and look at it .
DCL, July 2010
There are two or three possible answers:
Hot water sensor is fauly:
CH filter is blocked:
Domestic Heat Exchanger is blocked:

Depending on the installation (ie new boiler on old system and the system not being correctly cleaned during install), the latter two are the most likely possiblity.

If it is a new boiler on a new system (cleaned correctly) the sensor becomes a possibilty.

Carefree, July 2010
link Click here to see other fixes for Ariston Mircrogenus HE 32 MFFI.