try the air pressure tube at the back of the drum. It can get full of gunk and not work. Take the back plate offf and locate the tube. Remove the tube from the switch, should pull off, and then blow down the tube. If it's blocked keep blowing until the obstruction is removed.
Zaffa, August 2010