Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Jerry asked ... Alpine 7287?    |    Guy asked ... Gaggenau fridge alarm problem?    |    Click here to ask your question

greenstar 24i. No hot water?

No hot water delivery, the boiler kettles on the main heat exchanger with HW demand. Central heating demand no problems. A brief history, the previous owners had the rad circuits replaced as the pipework was blocked. Upon purchase of property I moved the boiler to the loft without using the appliance. My guess is the small heat exchanger . Upon kettling the boiler stops as normal there is no flashing blue lights and do'es not require resetting
bob, September 2010
Found the answer myself. HW Bypass valve blocked with debri also heat exchanger littered with debri having flushed the boiler out everything ok.

bob, September 2010