58 mins ago andrew asked ... "SECURE" on a yellow backround, and I cant ge?    |    Melodie asked ... How do I remove and change the basket? Duratech Identity Gu?    |    Kathy asked ... Samsung ER-4915?    |    Mark asked ... Oven door removal?    |    Jt asked ... Where to buy mt270x petrol cap?    |    Click here to ask your question

Vokera Linea Max - hot cycling after re pressurising expansion vessel?

I have re pressurised the expansion vessel to 12psi having isolated and drained the boiler. The vessel now holds it's pressure, valve is dry and no signs of water from prv / external drain pipe. No error code on boiler.
Boiler pressure restored to 1bar cold, water clean.
On start up. the boiler will heat correctly to lower temperatures, both HW & CH (60 Deg os so).
However, when the temperature is set to Max, the stystem will heat to around 85 Deg but the boiler then cycles hot - the boiler coming on every 20-30 seconds and running for about the same? Boiler pressure will increase to around 2 bar.
Any ideas much appreciated.
maccag, September 2010
link Click here to see other fixes for Vokera Linea Max.