i have 7 radiators in my house only 2 of them will work they wont heat up and my house is freezing. what is wrong andx how can i fix ive already tried bleeding them that did not work ..........................?
Peccavi BG charge £595 i've had it done after numerous cowboys trying to sort ! so DO try BG cut out the middle man I say !
Marie Hodgkinson, September 2010
Get your heating on and turn all the radiators off - turn on one at a time to see if it warms up then turn it off and check the next one. Thermostatic Rad Valves have a control pin under the control head - sometimes they get stuck down in the off position - take off the head and pull the pin up.. Tweak up the thermostat on the Boiler just a bit to just past mid way - speed up the circulating pump by adjusting the control. If you're content that all the rads can give off heat then go through a balancing exercise to ensure that each one gets its fair share of hot water. If all this fails to work call in an expert but avoid British Gas who will want to power flush your system for £700.