GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

no hot water sime super 90?

when i run my hot water tap slow the water goes cold and the boiler cuts out
alan, October 2010
A combi boiler requires a certain flow rate at the tap to stop boiler from overheating and cutting out. So by cutting back your tap to slow , you are not allowing this and the boiler is cutting out. Open your taps more to allow a good flow rate, if water not warm enough then flow rates have to be adjusted by gas boiler engineer. If this doesn't help u have a diverter valve problem.

simeservicesscotland.com, October 2010