Dwayne B. asked ... Intermittent (twice) Then Complete Loss of Power?    |    Aunt Bee asked ... Bernina Update 1630 work light not working?    |    Larry asked ... Hybrid Weed wacker not working with battery?    |    Dan asked ... Why is Google Keep so slow on my iPhone?    |    dave s asked ... Transmission not working?    |    Click here to ask your question

no hot water sime super 90?

when i run my hot water tap slow the water goes cold and the boiler cuts out
alan, October 2010
A combi boiler requires a certain flow rate at the tap to stop boiler from overheating and cutting out. So by cutting back your tap to slow , you are not allowing this and the boiler is cutting out. Open your taps more to allow a good flow rate, if water not warm enough then flow rates have to be adjusted by gas boiler engineer. If this doesn't help u have a diverter valve problem.

simeservicesscotland.com, October 2010