andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Click here to ask your question

no hot water sime super 90?

when i run my hot water tap slow the water goes cold and the boiler cuts out
alan, October 2010
A combi boiler requires a certain flow rate at the tap to stop boiler from overheating and cutting out. So by cutting back your tap to slow , you are not allowing this and the boiler is cutting out. Open your taps more to allow a good flow rate, if water not warm enough then flow rates have to be adjusted by gas boiler engineer. If this doesn't help u have a diverter valve problem.

simeservicesscotland.com, October 2010