Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    tom schwartz asked ... Bosch maxx 6?    |    Noman asked ... Reverse light switch?    |    Suzie asked ... Stuck Feed dog?    |    Click here to ask your question

vokera syntesi boiler over gassing?

i have a vokera syntesi boiler and its started to cough and splutter very loudly as soon as you switch it on. I have been told that it might be over gassing which it is as we checked it with a gauge.

Is it possible to turn the pressure down on the boiler or do i need a new gas regulator. Your advice would be great...
Tony, November 2010
u need 2 check the data bage and it tells u clearly the burner pressures on min and max,take it ur regestered!that boiler has a modulation gas valve on it!i have found in the past that some1 alredy messed up the settings on them that doesnt know what thay are doin,its unlikly that the valve is faulty just been touched when shouldnt have!check and see if it modulates,could be a blocked heat exchanger!

peter dublin, November 2010