22 mins ago katlego asked ... Rev count on my 1982?    |    andrew asked ... "SECURE" on a yellow backround, and I cant ge?    |    Melodie asked ... How do I remove and change the basket? Duratech Identity Gu?    |    Kathy asked ... Samsung ER-4915?    |    Mark asked ... Oven door removal?    |    Click here to ask your question

potterton boiler wont ignite?

my boiler wont ignite had it pressure tested it passed that so was told it cant be gas .code e1.33 keeps flashing it goes throw cycle but wont ignite had one of the spark type plugs out tested it it sparked .so now we are stuck /
m mcaleavey, November 2010
you'll need to have you're co2 ratio's re-set. job for a qualified engineer with a performance tester / telegan. if unable to re-set ratio's then new gas valve required. relatively common problem, which is less likely to occur if it's being serviced properly.

Ian, November 2010
link Click here to see other fixes for Potterton E1.33.