2 hours ago Jo asked ... How to engage clutch on old sewing machine to engage needle?    |    Jacky asked ... Miele Vacuum cleaner?    |    Ben asked ... Toyota Yaris French or Japanese?    |    Andy asked ... How can I mend my MacAlistair 450w hedge trimmer?    |    Felix asked ... Hitachi vt-m70em?    |    Click here to ask your question

baxi 105e pressure exceeds 3 bar?

My baxi boiler keeps going up tp 3.5 bar pressure when i put the heating on even though the pressure is only at 1 bar when cold. Can anyone tell what the problem is ?
steve, December 2010
Expension vessel faulty, fill pressure to 1 bar when system pressutre to zero, and if fault continue than add another vessel to heating system elsewhere

k, December 2010
either pipe to pressure vessel is blocked, the vessel needs to be repressurised or the vessel faulty

brian, December 2010