Morne asked ... My defy dtl 125 toploader?    |    Ernie asked ... How to fix gearchange ldv maxus van 2006?    |    Cuckoo asked ... Changing batteries on a fixed bt corded phone?    |    Marc Nollid asked ... Nissan Micra mk 5 2018 rear seat mecanism?    |    Maggie asked ... New Home 535?    |    Click here to ask your question

How Do I Reset my Greenstar 30Si Combi Boiler?

I have no hot water or heating.
I've checked the pressure gauge and set it to 1.5.
I've switched it off at the mains and left it for a short while before switchinbg it on and trying to reset it.
It sounds like it's kicking in and the burner indicator comes on, but after a short while goes back off again.
How do i solve this?
Stu B, December 2010
Flame rectification sounds to be failing, check the condense waste pipe is clear, especially the inital trap which tends to block with sand from the main heat exchanger (the sand is residue from when the heat exchanger was cast).

Carefree, December 2010
link Click here to see other fixes for Worcester Bosch Greenstar 30Si.