narnia asked ... Matsui ct-111ss?    |    Jason asked ... How to fix handset problems ( intercom ) and access control?    |    andy asked ... Samsung VP-D60 camcorder?    |    Shopper asked ... Poor Renault Radio Reception?    |    reg bardle asked ... Lg 7kg dd?    |    Click here to ask your question

vailant boiler ecotec plus?

boiler won t come 0n gettiing f.75 on display what does that mean or how d0 i rest
wasif shah, December 2010
F75 Can be simply re-pressuring the boiler, press the minus button below the display, this will give you a reading of the system pressure, if below 1 bar, it will need topping up by using the two grey taps underneath the boiler.
It can also be either the pressure sensor faulty, or a faulty pump (the former being more likely).

Reset the boiler by pressing the button (flame with a cross through it) to reset the boiler, if the fault returns, get an RGI to check the actual cause. It'll be as written above.

Carefree, December 2010