Suzanne asked ... Washing programme stops after 3 minutes?    |    Rif asked ... Kenwood Dishwasher KID60S20 leaking from front?    |    Fraser asked ... Spares for power craft ppcs 38cc?    |    FB asked ... Toyota Yaris Speed Camera Warning Beep?    |    Ela asked ... Worcester 30 Cadillac combi boiler won’t fire up and the EA?    |    Click here to ask your question

how can i increase the pressure on a Ravenheat combi boiler?

the pressure has dropped to between 0 & 1 therefore the system will not come on. After turning the system off, where do i locate the pressure lever to amend this issue?
Brian, January 2011
there should be a filling loop, from teh cold water pipe to the boiler, sometimes they are unscrewed after filling. (one end dangles free) sometimes left connected, just turn the inline tap until you get the pressure you require, then turn off the tap, if you put in too much, there is a red release knob on the overflow valve on the right hand side

andyx, January 2011