GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

vaillant boiler?

the red light has come on and f75 no heating please advise vaillant ecotec
linda, January 2011
I have had the PCB changed last week on my Combi Thermo plus boiler, from that time my thermostat is not signalling the right temperature. I set it on 23 degrees and it stays oon 19 to 20.5. It does not go higher.

bibi, January 2011
F75 points to a few possible problems, hopefully for you not too serious.

There are four buttons under the display, the top left one resets the boiler, while the boiler is going through its start up check, press the bottom left ( - ) button, this will tell you on the display how much pressure is in the boiler (measured in bars), if it's below 1.0, top it up until it reaches between 1 & 1.5bar Just keep pressing the minus button to see the pressure.

If that doesn't sort it and F75 re-appears, you will need to call someone in, as either the pressure sensor or pump will be faulty.

Carefree, January 2011
link Click here to see other fixes for Vaillant.