Alan asked ... Problem with JCB 3CX transmission?    |    Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Click here to ask your question

How can I turn the power on for Ferroli Optimac HE 31S?

We had a power issue, the trip switch for the heating was off this morning. After I put the trip back on, the was still no power to the boiler. The is nothing on the biolder display. I've tried holding the on button for 5 secs, but it doesn't work. The Centaur timer displat is working, but the boiler is not responding to it.

How can I turn the boiler on?
AH, February 2011
A lot depends on why the trip switch was off?

Inital check for 220~240v on the boiler terminal strip, then check the on board fuses and replace as necessary. Be aware, if the fuses blow, there is possibly an internal component causing the rcd to trip in the first place.

Best get a gas safe engineer to check it properly.

Carefree, February 2011
link Click here to see other fixes for Ferroli.