Carol asked ... How to remove roller from lawnmower?    |    Ariana Orellana asked ... Code?    |    Lynnie asked ... BT Studio 4500 cordless telephone?    |    David Dawes asked ... How to recoil the starter spring - Champion R484TR?    |    peter high asked ... How can I set time on my Neff oven?    |    Click here to ask your question

potterton puma 80?

hi i have a potterton puma 80 combi boiler, the pressure light comes on after about 8 hours of intermittent use and needs re-filling and will then work for another 8 hours befor it needs re-filling again, anyone any ideas thanks
chris, February 2011
You have a leak on the system somewhere.
When using the heating, keep an eye on the pressure on the guage, if it rises significantly (towards or past the red point), the system will most likely be losing pressure through the prv, this would mean the expansion vessel needs recharging/replacing.

Carefree, February 2011