3 hours ago Jo asked ... How to engage clutch on old sewing machine to engage needle?    |    Jacky asked ... Miele Vacuum cleaner?    |    Ben asked ... Toyota Yaris French or Japanese?    |    Andy asked ... How can I mend my MacAlistair 450w hedge trimmer?    |    Felix asked ... Hitachi vt-m70em?    |    Click here to ask your question

boiler pipe out side leeks hot water?

my combie boiler pipe outside has hot water dripping out
charlotte mac, February 2011
Presure vessel may have lost its charge

Barrie, February 2011
If dripping pipe is copper and external to property, then it is the pressure relief pipe. This should only discharge water if it boiler system pressure has become excessive, or if the pressure relief valve (PRV) is faulty and is constantly passing water.
If former is the case, establish why excess pressure.
In the case of constant drip, then chang prv.

richard, February 2011
check the pressure dial should read 1.5 bar, check the filling loop are the valves turned off fully, if after two days still dripping call in a gas safe eng

erj, February 2011