andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Click here to ask your question

Baxi problem?

my boiler seems to have problem.
I am trying to refill it but i now can't remove the filling loop as the ch outlet leaks water despite valve being closed. Could there be a simple solution
Milky71, March 2011
should be a non return vale one end of loop and isolating valve the other.if a plastic black handle on iso valve,take screw out and take plastic head off thencheck with spanner that valve is deff closed.if still leeking,you ll need to drain system,get all water out then replace old loop with new one.

mr combi, March 2011