low water pressure Ideal Combi boiler?

I have an Ideal Independant C30 boiler that has low water pressure, there are 4 taps underneath and I do not know which ones to turn to bring the pressure back up - any help please?
Jayne H, May 2011
My boiler says l2 Iv tried resetting it but no luck now it's saying 0 and the water and heating still isn't working. Can you give me any advice please

Matthew stephenson, January 2017
There will probably be a short flexible hose with a tap at each end underneath the boiler. When both taps are open, typically when the handles are in-line with the hose, mains water will enter the system.
Keep watching the pressure gauge and turn back off at both ends once the pressure reaches around 1.5 bar.

Adam, May 2011