4 hours ago Karen asked ... Royal 480nt cash register?    |    andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    Click here to ask your question

vokera maxin 24e?

The gas keeps going out when i try to heat the water then it will ignite then go out then reignite then go out
lee owens, June 2011
hi lee, this is a discontinued boiler so i assume fairly old. the domestic hot cycling as it is, is due to the flow through the heat exchanger being insufficient and making boiler overheat and cut out on overheat thermostat. It then cools down and relights. This could be due to limescale or a dirty heat exchanger. If it works ok on heating its probably just the domestic hot water heat exchanger. or the diverter valve. Either way it needs cleaning or replacing.

johnokent, June 2011