Andrew - C asked ... Stannah 400?    |    Liam asked ... Belts for old WEBB Mower?    |    Leith asked ... Bosch Classix Type WKM41 front loader washing machine?    |    Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    Click here to ask your question

Boiler pressure?

i have a glowworn compact 75.It pressure bar is on zero it should be on .7 bar.Before that it was on .7 bar .Now i dont know how i can fix this problem .
hanzala, September 2006
The filling loop should not be attached to the boiler/system, water byelaws...If it is repressurise system by turning opening valves at each end of the braided filling loop to 1 bar then bleed every radiator making sure the pressure is topped up/replaced - turn off and remove the Filling loop. If you cannot understand this call a Corgi registered heating engineer.

Brian, September 2006
it needs refill with the filling loop under the boiler you'll see a flexable braided pipe thats the filling loop from the mains water

hi-spec plumbing, September 2006