jam a socket extension in the pulley and in to the holes in the back of the tub.using a 17mm socket turn it anticlockwise.wiggle pulley side to side whilst pulling until it pops of the drum shaft or carefully lever.whole tub has to be removed from the cabinet and split to replace the bearings and seal
ck, July 2011