andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Click here to ask your question

How do I fix a Potterton Prima 80 Boiler Igniton?

Just fired up a Potterton Prima 80 Boiler today for the first time in 10 months. Worked fine at first, then went to continuous sparking of igniter and pilot on only. Main burner not kicking in. Any suggestions?
Ronnie, September 2011
Ronnie,
same thing happened to my potterton boiler. I needed a mercury switch which was quite cheap and it was fitted by gas board fitter i n .a few minutes.

Clive, September 2011
if the pilot is lit but is continuosly sparking then you need a new pcb, it's quite common.
if the pilot and the main burner light then it goes back to pilot only, with no sparking, then the gas valve is faulty.

Ian, September 2011
link Click here to see other fixes for Potterton Prima 80.