Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

baxi solo 3 pfl 30/80 boiler?

Brrr Hello! We have two lights on - boiler & fan but no ignition or signs of wanting to ignite ie clicking. Any thoughts on the problem are verrrrryy welcome.
Thanks
mick. y, November 2011
When the fan runs it makes a circuit through the air pressure switch and then ignition commences, no ignition with the fan running points to the APS. If the APS is closed circuit and it has no voltage through it then the control pcb may be faulty, if the APS is open circuit with the fan running, and has voltage waiting , then the APS is faulty. This is assuming the fan is in good condition and running at normal speed.

Jonny, November 2011
link Click here to see other fixes for Baxi Solo 3.