GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

baxi genesis 80 boiler?

have changed 3 way valve problem with no ch, this now works but pressure rising above 3 bar if boiler is used on full temp temp left at half it stays at 2.5 bar?
peter, November 2011
You will find that the expansion vessel has lost it charge. You can repressurise by using a foot pump up to 1 bar of pressure and make sure that the system has no pressure in it otherwise it will give you false readings and its normally sited at the back of the boiler

dmh, November 2011
link Click here to see other fixes for Baxi.