Suzanne asked ... Washing programme stops after 3 minutes?    |    Rif asked ... Kenwood Dishwasher KID60S20 leaking from front?    |    Fraser asked ... Spares for power craft ppcs 38cc?    |    FB asked ... Toyota Yaris Speed Camera Warning Beep?    |    Ela asked ... Worcester 30 Cadillac combi boiler won’t fire up and the EA?    |    Click here to ask your question

fix low pressure on my boiler?

i have a F37 error on a ferroli boiler. i keep reading about the filling loop but nothing underneath matches the description
keith, December 2011
Filling lop is a flexible metal braided pipe, with a valve, and a non-return valve. Might not be below your boiler. look for a metal braid pipe. Some times, not left connected, Officially, should not be left connected. So look for 2 pipe screw fittings, max about 10inches apart. one would be your cold water mains supply pipe, the other would go to the return of your central heating system. If not there, go and get one. fit it, and off you go.

SD, December 2011