andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Click here to ask your question

Honeywell 3 way valve?

I have a Honeywell 3 way valve on between my HW & CH. It is wired to a Potterton Controller.
Currently the CH comes on when the HW is on with no control.
Can anyone advise a procedure for checking the 3 way valve.
It has a auto and manual switch fitted to the side which is currently set to AUTO.
Regards
Mark
Mark, October 2006
turn off electrics does lever on side of valve now move freely.does it make a kind of whirring noise when pushed right across.if it is stuck then its the synchron motor ,that as gone if it does move then the ball inside the valve is passing , that is presuming that it has at sometime previously worked right?

paul, October 2006