Morne asked ... My defy dtl 125 toploader?    |    Ernie asked ... How to fix gearchange ldv maxus van 2006?    |    Cuckoo asked ... Changing batteries on a fixed bt corded phone?    |    Marc Nollid asked ... Nissan Micra mk 5 2018 rear seat mecanism?    |    Maggie asked ... New Home 535?    |    Click here to ask your question

Problems with a Potterton Netaheat 10-16 Boiler?

Even with the central heating turned off the radiators come on with the hot water. I assume this must be an electrics problem. Is the main PCB faulty. Any advice gratefully received.
Alan Matthews, October 2006
i presume you have a open vent sysyem (header/expansiontank ect) almost certainly your motorised valve which controls the route of flow to c/h , h'w or both is not operating properly and there fore allowing flow around all pipework, rather than shutting the entry to the c/h when in hot water mode. you can check by alternating h/w -c/h call up and seeing if the valve moves to its appropiate position.

Desman, October 2006