GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

Problems with a Potterton Netaheat 10-16 Boiler?

Even with the central heating turned off the radiators come on with the hot water. I assume this must be an electrics problem. Is the main PCB faulty. Any advice gratefully received.
Alan Matthews, October 2006
i presume you have a open vent sysyem (header/expansiontank ect) almost certainly your motorised valve which controls the route of flow to c/h , h'w or both is not operating properly and there fore allowing flow around all pipework, rather than shutting the entry to the c/h when in hot water mode. you can check by alternating h/w -c/h call up and seeing if the valve moves to its appropiate position.

Desman, October 2006