Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

Glowworm Flexicom F1 F4 faults?

Having a problem with boiler cutting out. NOT a condensate problem. Key bit of information is that it will run in central heating but after a hot water tap has been used it won't continue with central heating, get F1. Also, if when running in central heating and boiler water at say 80deg the temperature is reduced to 75deg ( so that boiler cuts out) then increased back to 80deg ( so that boiler tries to come back in) get failure F4. What could cause this?
Mike D, February 2012
Have now changed the electrode and the boiler is running fine.... for now!

Mike D, February 2012