Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

Ravenheat CSI 120 error code 04?

I have a Ravenheat CSI 120 on which I recently (last week) replaced the diaphragm in the diverter valve. I then vented the system, as best I could, by bleeding the radiators. Everything worked fine until this morning when the heating cut out, both CH and DHW, and the boiler showed an 04 error code, which is overheat lockout. After that the boiler would not start and continues to display the 04 code. I checked the overheat thermostat with a test meter and got continuity, which I assume is as it should be, and I am now a bit flummoxed as to what to do next. Could it be that I have not properly vented the boiler after removal and replacement of the diverter valve? Any help would be appreciated.
vbiter, February 2012
UPDATE
Through a process of elimination I discovered that the DHW sensor was faulty. I don't know why this would give an overheat lockout error on the central heating system but I replaced it and everything now works fine - for the moment!